Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
1.
Circ Cardiovasc Interv ; : e013794, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38629311

RESUMO

BACKGROUND: The extent of cardiac damage and its association with clinical outcomes in patients undergoing transcatheter edge-to-edge repair (TEER) for degenerative mitral regurgitation remains unclear. This study was aimed to investigate cardiac damage in patients with degenerative mitral regurgitation treated with TEER and its association with outcomes. METHODS: We analyzed patients with degenerative mitral regurgitation treated with TEER in the Optimized Catheter Valvular Intervention-Mitral registry, which is a prospective, multicenter observational data collection in Japan. The study subjects were classified according to the extent of cardiac damage at baseline: no extravalvular cardiac damage (stage 0), mild left ventricular or left atrial damage (stage 1), moderate left ventricular or left atrial damage (stage 2), or right heart damage (stage 3). Two-year mortality after TEER was compared using Kaplan-Meier analysis. RESULTS: Out of 579 study participants, 8 (1.4%) were classified as stage 0, 76 (13.1%) as stage 1, 319 (55.1%) as stage 2, and 176 (30.4%) as stage 3. Two-year survival was 100% in stage 0, 89.5% in stage 1, 78.9% in stage 2, and 75.3% in stage 3 (P=0.013). Compared with stage 0 to 1, stage 2 (hazard ratio, 3.34 [95% CI, 1.03-10.81]; P=0.044) and stage 3 (hazard ratio, 4.51 [95% CI, 1.37-14.85]; P=0.013) were associated with increased risk of 2-year mortality after TEER. Significant reductions in heart failure rehospitalization rate and New York Heart Association functional scale were observed following TEER (both, P<0.001), irrespective of the stage of cardiac damage. CONCLUSIONS: Advanced cardiac damage is associated with an increased risk of mortality in patients undergoing TEER for degenerative mitral regurgitation. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: UMIN000023653.

3.
Heart Vessels ; 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38329512

RESUMO

For pre-procedural planning of left atrial appendage (LAA) closure, sizing is crucial. Although transesophageal echocardiography (TEE) is a standard modality, cardiac computed tomography (CT) is also widely used. The virtual TEE (V-TEE) that our group developed enables us to reconstruct images similar to TEE images from CT images. The software should be helpful to understand and plan the procedure strategy. Accordingly, we investigated the utility of V-TEE. Sixty-six patients at 4 participating sites who completed both CT and TEE prior to LAA closure were included. The LAA diameter at the landing zone (LZ) for WATCHMAN™ device implantation was statistically compared at 0°, 45°, 90°, and 135° between V-TEE and TEE. Among 66 cases, only 3 cases were excluded due to poor imaging quality, and 63 cases were analyzed. The device LZ diameters based on V-TEE were strongly correlated with those based on TEE, despite the significantly greater diameter based on V-TEE with mean differences of 2.4 to 3.0 mm (all of them: P < 0.001). The discordances (V-TEE/TEE ratio) at most angles were significantly larger in the elliptical LAAs. V-TEE provides a valuable method for the evaluation of the LAA diameters. V-TEE-based measurements were larger than conventional TEE-based measurements, especially in cases of elliptical LAAs. The assessment by V-TEE has the potential benefit of ensuring proper device sizing regardless of the LAA morphology.

4.
J Clin Med ; 13(3)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38337545

RESUMO

Background: Transcatheter edge-to-edge mitral valve repair (TEER) has emerged as a viable approach to addressing substantial secondary mitral regurgitation. In the contemporary landscape where ultimate heart failure-specific therapies, such as cardiac replacement modalities, are available, prognosticating a high-risk cohort susceptible to early cardiac mortality post-TEER is pivotal for formulating an effective therapeutic regimen. Methods: Our study encompassed individuals with secondary mitral regurgitation and chronic heart failure enlisted in the multi-center (Optimized CathEter vAlvular iNtervention (OCEAN)-Mitral registry. We conducted an assessment of baseline variables associated with cardiac death within one year following TEER. Results: Amongst the 1517 patients (median age: 78 years, 899 males), 101 experienced cardiac mortality during the 1-year observation period after undergoing TEER. Notably, a history of heart failure-related admissions within the preceding year, utilization of intravenous inotropes, and elevated plasma B-type natriuretic peptide levels emerged as independent prognosticators for the primary outcome (p < 0.05 for all). Subsequently, we devised a novel risk-scoring system encompassing these variables, which significantly stratified the cumulative incidence of the 1-year primary outcome (16%, 8%, and 4%, p < 0.001). Conclusions: Our study culminated in the development of a new risk-scoring system aimed at predicting 1-year cardiac mortality post-TEER.

5.
Circ J ; 2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38267035

RESUMO

BACKGROUND: Clinical outcomes after percutaneous coronary intervention have improved with the use of drug-eluting stents, but data beyond 10 years are limited. The purpose of this study was to evaluate the clinical outcomes of patients undergoing sirolimus-eluting stent implantation with follow-up beyond 10 years and to determine the impact of clinical and angiographic characteristics on long-term prognosis.Methods and Results: The clinical outcomes of 885 patients who had undergone sirolimus-eluting stent implantation at a single institution were retrospectively reviewed. Primary endpoints included in the analysis were clinically driven target lesion revascularization (cTLR) and target lesion revascularization (TLR). Univariate and multivariate nominal logistic regression was used for data analysis. The incidence rates of cTLR and TLR beyond 10 years after sirolimus-eluting stent implantation were 16.4% and 36.8%, respectively, with cTLR tending to decrease beyond 10 years. Acute coronary syndrome was a predominant trigger for cTLR. Age, statin use, and stent restenosis emerged as predictors of cTLR within 10 years, but no significant predictors other than age were identified beyond 10 years. CONCLUSIONS: Events continue to occur beyond 10 years after sirolimus-eluting stent implantation, with a trend toward an increase in acute coronary syndromes. It is important to be vigilant about the occurrence of acute coronary syndromes during long-term follow-up.

6.
J Echocardiogr ; 22(1): 16-24, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37644318

RESUMO

BACKGROUND: In left atrial appendage closure using WATCHMAN FLX, accurate device measurement by transesophageal echocardiography (TEE) is important. We aimed to experimentally validate appropriate methods of device measurement with two-dimensional (2D) and three-dimensional (3D) TEE compared with actual size. METHODS: We prepared a full range of device sizes (20, 24, 27, 31, 35 mm), each with five different compression rates. Each device was measured by 2D and 3D TEE at depths of 2, 4, and 6 cm in vitro using inner, outer, and middle line methods. We compared the difference between the actual size by caliper and measurements at each compression rate and depth by the three methods in 2D and 3D TEE. RESULTS: A total of 450 patterns of measurements were analyzed. The differences using the middle line method were much less than those using the inner and outer line methods in 2D and 3D TEE (2D TEE: 0.45 ± 0.36 vs. 2.55 ± 0.99 vs. 2.59 ± 0.72 mm, p < 0.01; 3D TEE: 0.34 ± 0.27 vs. 2.38 ± 0.69 vs. 1.86 ± 0.77 mm, p < 0.01). Moreover, the differences in measurements by 3D TEE were more accurate than those of 2D TEE in the inner (2.47 ± 1.86 vs. 1.86 ± 0.77 mm, p < 0.01) and middle (0.58 ± 0.37 vs. 0.34 ± 0.27 mm, p < 0.01) line methods. CONCLUSIONS: Middle line method by 3D TEE is the most reliable approach for device measurement at left atrial appendage closure using WATCHMAN FLX device.

8.
Artigo em Inglês | MEDLINE | ID: mdl-38064131

RESUMO

Contrast media are generally necessary for transcatheter left atrial appendage closure (LAAC), however, it should be avoided in patients with chronic kidney disease (CKD). The objective of this study was to evaluate the safety and feasibility of contrast-free LAAC with WATCHMAN FLX device for patients with CKD. Among 141 patients undergoing LAAC using the WATCHMAN FLX between May 2021 and March 2023, we performed LAAC without contrast media in 10 patients. Procedural and follow-up results were evaluated. The device size was selected based on the transesophageal echocardiographic (TEE) measurements. The device shape was assessed by fluoroscopy, and the device position was adjusted by TEE images. The mean age was 78 ± 4.9 years, CHADS2 score was 3.2 ± 1.1, and the estimated glomerular filtration rate (eGFR) was 28 ± 12 mL/min/1.73m2. The procedure was completed without contrast media in ten patients. Partial recapture of the device was required in four patients, but the initially selected device was finally implanted in all patients. Mean procedure time was significantly shorter in the contrast-free LAAC than in the contrast-use LAAC (41.6 ± 14.1 min vs 30.3 ± 7.6 min, p = 0.01). Postprocedural eGFR did not change from baseline, and there were no adverse events during the hospital stay. Follow-up TEE or cardiac computed tomography performed within 3 months after the procedure revealed no device-related thrombus or peri-device leak > 3 mm, and oral antithrombotic therapy was discontinued in all patients. Our experience shows that contrast-free LAAC using the WATCHMAN FLX device was safe and feasible. Non-contrast LAAC is one of the therapeutic options for patients with severe CKD.

9.
JACC Asia ; 3(5): 766-773, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38094997

RESUMO

Background: Transcatheter edge-to-edge repair (TEER) is a less invasive treatment for patients with mitral regurgitation (MR). Limited safety and efficacy data of TEER with MitraClip, including the fourth-generation (G4) system, in a large cohort, are available. Objectives: This study aimed to summarize the initial experience of the TEER system in patients with MR from a large registry in Japan. Methods: The OCEAN (Optimized CathEter vAlvular iNtervention)-Mitral Registry is an ongoing, prospective, investigator-initiated, multicenter, observational registry for patients with primary and secondary MR undergoing transcatheter mitral valve therapies. A total of 21 centers participated in the registry. Patients undergoing TEER were enrolled, and their characteristics, procedural details, and clinical outcomes were recorded. Results: In total, 2,150 patients including 1,605 patients (75.0%) with secondary MR, were enrolled between April 2018 and June 2021. The median age was 80 years, and 43.7% were women. The median device and fluoroscopy times were 60 and 26 minutes, respectively. Those with the G4 system (618/2,150 [28.7%]) were significantly shorter than those with the second generation (G2) system (1,532/2,150 [71.3%]). Overall, 94.6% met acute procedural success without significant differences between the 2 systems (G2 94.7% vs G4 94.6%; P = 0.961). Conclusions: The OCEAN-Mitral registry has demonstrated the short-term outcomes of TEER systems, including the G4 system, in symptomatic patients with primary and secondary MR. The acute procedural success rate in the G2 system was excellent, and that in the G4 system was expected to improve with the multidisciplinary heart valve team approach. (Japanese Registry study of valvular heart diseases treatment and prognosis; UMIN000023653).

10.
Circ J ; 88(1): 127-132, 2023 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-37899174

RESUMO

BACKGROUND: Evidence is limited regarding long-term clinical outcomes after alcohol septal ablation (ASA) for patients with hypertrophic obstructive cardiomyopathy and its periprocedural predictive factors in Japan.Methods and Results: This retrospective observational study included 44 patients who underwent ASA between 1998 and 2022 in a single center. We evaluated the periprocedural change in variables and long-term clinical outcomes after the procedure. The primary outcome was a composite of cardiovascular death or hospitalization for heart failure. The secondary outcome was all-cause death. Using multivariable Poisson regression with robust error variance, we predicted underlying periprocedural factors related to primary outcome development. ASA decreased the median pressure gradient at the left ventricular outflow tract from 88 to 33 mmHg and reduced moderate or severe mitral regurgitation (MR), present in 53% of patients before ASA, to 16%. Over a median 6-year follow-up, the cumulative incidence of the primary outcome at 5 and 10 years was 16.5% and 25.6%, respectively. After multivariable analysis, moderate or severe MR after ASA was significantly associated with the primary outcome (relative risk 8.78; 95% confidence interval 1.34-57.3; P=0.024). All-cause mortality after ASA was 15.1% and 28.9% at 5 and 10 years, respectively. CONCLUSIONS: This study presents long-term clinical outcomes after ASA in Japan. Moderate or severe MR after ASA was significantly associated with the composite of cardiovascular death or hospitalization for heart failure.


Assuntos
Técnicas de Ablação , Cardiomiopatia Hipertrófica , Insuficiência Cardíaca , Humanos , Técnicas de Ablação/efeitos adversos , Técnicas de Ablação/métodos , Cardiomiopatia Hipertrófica/cirurgia , Cardiomiopatia Hipertrófica/complicações , Etanol , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/complicações , Japão , Estudos Retrospectivos , Resultado do Tratamento , Septos Cardíacos
11.
J Am Heart Assoc ; 12(20): e030747, 2023 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-37815039

RESUMO

Background Limited data are available about clinical outcomes and residual mitral regurgitation (MR) after transcatheter edge-to-edge repair in the large Asian-Pacific cohort. Methods and Results From the Optimized Catheter Valvular Intervention (OCEAN-Mitral) registry, a total of 2150 patients (primary cause of 34.6%) undergoing transcatheter edge-to-edge repair were analyzed and classified into 3 groups according to the residual MR severity at discharge: MR 0+/1+, 2+, and 3+/4+. The mortality and heart failure hospitalization rates at 1 year were 12.3% and 15.0%, respectively. Both MR and symptomatic improvement were sustained at 1 year with MR ≤2+ in 94.1% of patients and New York Heart Association functional class I/II in 95.0% of patients. Compared with residual MR 0+/1+ (20.4%) at discharge, both residual MR 2+ (30.2%; P < 0.001) and 3+/4+ (32.4%; P = 0.007) were associated with the higher incidence of death or heart failure hospitalization (adjusted hazard ratio [HR], 1.59; P < 0.001, and adjusted HR, 1.73; P = 0.008). New York Heart Association class III/IV at 1 year was more common in the MR 3+/4+ group (20.0%) than in the MR 0+/1+ (4.6%; P < 0.001) and MR 2+ (6.4%; P < 0.001) groups, and the proportion of New York Heart Association class I is significantly higher in the MR 1+ group (57.8%) than in the MR 2+ group (48.3%; P = 0.02). Conclusions The OCEAN-Mitral registry demonstrated favorable clinical outcomes and sustained MR reduction at 1 year in patients undergoing transcatheter edge-to-edge repair. Both residual MR 2+ and 3+/4+ after transcatheter edge-to-edge repair at discharge were associated with worse clinical outcomes compared with residual MR 0+/1+. Registration Information https://upload.umin.ac.jp. Identifier: UMIN000023653.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Fatores de Risco , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Hemodinâmica , Sistema de Registros
12.
J Cardiol ; 2023 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-37802202

RESUMO

BACKGROUND: Percutaneous left atrial appendage closure (LAAC) has increased for those who need alternative to long-term anticoagulation with non-valvular atrial fibrillation (NVAF). METHODS AND RESULTS: From September 2019, after initiating WATCHMAN (Boston Scientific, Maple Grove, MN, USA) device implantation, we established Transcatheter Modification of Left Atrial Appendage by Obliteration with Device in Patients from the NVAF (TERMINATOR) registry. Utilizing 729 patients' data until January 2022, we analyzed percutaneous LAAC data regarding this real-world multicenter prospective registry. A total of 729 patients were enrolled. Average age was 74.9 years and 28.5 % were female. Paroxysmal AF was 37.9 % with average CHADS2 3.2, CHA2DS2-VASc 4.7, and HAS-BLED score of 3.4. WATCHMAN implantation was successful in 99.0 %. All-cause deaths were 3.2 %, and 1.2 % cardiovascular or unexplained deaths occurred during follow-up [median 222, interquartile range (IQR: 93-464) days]. Stroke occurred in 2.2 %, and the composite endpoint which included cardiovascular or unexplained death, stroke, and systemic embolism were counted as 3.4 % [median 221, (IQR: 93-464) days]. Major bleeding defined as BARC type 3 or 5 was seen in 3.7 %, and there was 8.6 % of all bleeding events in total [median 219, (IQR: 93-464) days]. CONCLUSIONS: These preliminary data demonstrated percutaneous LAAC with WATCHMAN device might have a potential to reduce stroke and bleeding events for patients with NVAF. Further investigation is mandatory to confirm the long-term results of this strategy using this transcatheter local therapy instead of life-long systemic anticoagulation.

13.
Eur Heart J Case Rep ; 7(9): ytad438, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37719004

RESUMO

Background: Leaflet tear and perforation are serious complications of transcatheter edge-to-edge repair (TEER) using the MitraClip system for severe mitral regurgitation (MR). However, no optimal bailout strategy has been established. Case summary: An 80-year-old woman developed heart failure due to acute ischaemic severe MR after primary percutaneous coronary intervention. Given the requirement for inotropic drugs and an intra-aortic balloon pump to stabilize her heart failure, we decided to perform TEER using the MitraClip G4 system. The NTW clip was selected considering the limited posterior leaflet, wide central MR, and delivery to the central A2/P2. The leaflet was successfully grasped, and the MR jet dramatically decreased while the clip was closed. However, the MR jet suddenly appeared after completely closing the clip arm. A new eccentric jet was detected coming from the mid-portion of the posterior leaflet, indicating leaflet perforation. We decided to manage the leaflet perforation by covering the perforated portion with a longer type of clip. An XTW clip was then carefully delivered to the previously grasped portion, after which we confirmed that the tip of the clip arm was positioned more posteriorly to the leaflet perforation. After slowly closing the clip, MR decreased to mild, with transoesophageal echocardiography showing no eccentric MR. After her haemodynamics stabilized, she was discharged 28 days after the procedure. Discussion: This case details a successful bailout clipping of a leaflet perforation using an XTW clip. Leaflet anatomy evaluation is important to ensure that the injured portion is covered by the longer clip arm.

14.
Am J Cardiol ; 205: 12-19, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37579655

RESUMO

Recent studies suggested short-term mortality after transcatheter edge-to-edge repair (TEER) was comparable between men and women. However, the gender-specific prognostic difference in the long-term follow-up after TEER is still unknown. To evaluate the impact of gender on long-term mortality after TEER for functional mitral regurgitation (FMR) using multicenter registry data. We retrospectively analyzed 1,233 patients (male 60.3%) who underwent TEER for FMR at 24 centers. The impact of gender on all-cause death and hospitalization for heart failure (HF) after TEER was evaluated using multivariate regression analysis and propensity score (PS) matching methods. During the 2-year follow-up, 207 all-cause death and 263 hospitalizations for HF were observed after TEER for FMR. Men had a significantly higher incidence of all-cause death than women (18.6% vs 14.1%, log-rank p = 0.03). After adjustment by multivariate Cox regression and PS matching, the male gender was significantly associated with a higher incidence of all-cause mortality after TEER than the female gender (hazard ratio 2.11, 95% confidence interval 1.42 to 3.14 in multivariate Cox regression; hazard ratio 1.89, 95% confidence interval 1.03 to 3.48 in PS matching). The gender-specific prognostic difference was even more pronounced after 1-year of TEER. On the contrary, there was no gender-related difference in hospitalization for HF after TEER. In conclusion, women with FMR had a better prognosis after TEER than men, whereas this was not observed in hospitalization for HF. This result might indicate that women with FMR are more likely to benefit from TEER.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Feminino , Masculino , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Hospitalização , Análise Multivariada , Resultado do Tratamento
15.
JACC Asia ; 3(2): 272-284, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37181391

RESUMO

Background: Limited data are available describing left atrial appendage closure (LAAC) and age-related outcomes in Asians. Objectives: This study summarizes the initial experience with LAAC in Japan and determines age-related clinical outcomes in patients with nonvalvular atrial fibrillation undergoing percutaneous LAAC. Methods: In an ongoing, prospective, investigator-initiated, multicenter, observational registry of patients undergoing LAAC in Japan, we analyzed short-term clinical outcomes in patients with nonvalvular atrial fibrillation who underwent LAAC. Patients were classified into younger, middle-aged, and elderly groups (≤70, 70 to 80, and >80 years of age, respectively) to determine age-related outcomes. Results: Patients (n = 548; mean age, 76.4 ± 8.1 years; male, 70.3%) who underwent LAAC at 19 Japanese centers between September 2019 and June 2021 were enrolled in the study, including 104, 271, and 173 patients in the younger, middle-aged, and elderly groups, respectively. Participants had a high-risk of bleeding and thromboembolism with a mean CHADS2 score of 3.1 ± 1.3, a mean CHA2DS2-VASc score of 4.7 ± 1.5, and a mean HAS-BLED score of 3.2 ± 1.0. Device success rates were 96.5% and anticoagulants discontinuation at the 45-day follow-up was achieved in 89.9%. In-hospital outcomes were not significantly different, but major bleeding events during the 45-day follow-up were significantly higher in the elderly group compared to the other groups (younger vs middle-aged vs elderly, 1.0% vs 3.7% vs 6.9%, respectively; P = 0.047) despite the same postoperative drug regimens. Conclusions: The initial Japanese experience with LAAC demonstrated safety and efficacy; however, perioperative bleeding events were more common in the elderly and postoperative drug regimens must be tailored (OCEAN-LAAC [Optimized Catheter Valvular Intervention-Left Atrial Appendage Closure] registry; UMIN000038498).

17.
Heart Vessels ; 38(2): 147-156, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35974254

RESUMO

The distal radial approach (DRA) has been proposed as an alternative approach for coronary angiography (CAG) and percutaneous coronary intervention (PCI); however, the predictors of DRA failure and puncture site complications are unclear. Among 7153 consecutive patients undergoing CAG or PCI between November 2018 and January 2021, 3610 patients undergoing CAG or PCI with DRA were analyzed. The primary endpoint of this study was the procedural success, and the secondary endpoint of this study was puncture site complications during procedure. Puncture site complications during procedure were defined as a composite of major bleeding, minor bleeding, arteriovenous fistula, pseudoaneurysm, and neuropathy. The DRA success rate and the puncture site complication rate were 90.4% and 7.7%, respectively. The predictors of DRA failure were low body weight and dual antiplatelet therapy; those of DRA success were PCI and ultrasonography-guided DRA; those of puncture site complications during procedure were low body weight, peripheral arterial disease, dual antiplatelet therapy, anticoagulant therapy, and PCI; and that of no puncture site complications were previous PCI and ultrasonography-guided DRA. The negative predictors of DRA success with no puncture site complication during procedure were low body weight and dual antiplatelet therapy. The positive predictor of DRA success with no puncture site complication during procedure was ultrasonography-guided DRA. We identified the predictors of DRA failure and puncture site complications during procedure in patients undergoing CAG and PCI with DRA. Ultrasonography-guided DRA was associated with a high DRA success rate and a low puncture site complication rate in patients undergoing CAG or PCI with DRA.


Assuntos
Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Inibidores da Agregação Plaquetária/uso terapêutico , Hemorragia/etiologia , Angiografia Coronária/efeitos adversos , Angiografia Coronária/métodos , Artéria Radial , Peso Corporal , Resultado do Tratamento
18.
Circ J ; 86(9): 1379-1387, 2022 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-35400715

RESUMO

BACKGROUND: The Academic Research Consortium for High Bleeding Risk (ARC-HBR) defined a consensus clinical criterion for patients at HBR undergoing percutaneous coronary intervention (PCI). This study aimed to validate and compare the ARC-HBR criteria and the contemporary risk score for long-term bleeding outcomes using a cohort of patients undergoing PCI.Methods and Results: This study analyzed 3,410 patients who underwent PCI between 2010 and 2013. The endpoint was defined as incidence of The Bleeding Academic Research Consortium 3 or 5 bleeding events. In addition to ARC-HBR, this study validated the predictability of the Predicting Bleeding Complications in Patients Undergoing Stent Implantation and Subsequent Dual Antiplatelet Therapy (PRECISE-DAPT) score, Patterns of non-adherence to Anti-platelet Regimens In Stented patients (PARIS) bleeding score, and Coronary Revascularization Demonstrating Outcome Study in Kyoto (CREDO-Kyoto) bleeding scores for bleeding events. There was a trend toward an increase in bleeding events, as the risk score increased for all bleeding risk scores used in this study. The ARC-HBR criteria had higher diagnostic sensitivity for bleeding events than other bleeding risk scores. CONCLUSIONS: Patients with a higher number of risk factors in each of the four bleeding risk scores had a higher risk of long-term bleeding events. In comparison to other contemporary risk scores, the ARC-HBR criteria were more sensitive in the identification of patients with bleeding events in the long-term.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Stents Farmacológicos/efeitos adversos , Hemorragia/epidemiologia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/efeitos adversos , Medição de Risco , Fatores de Risco , Resultado do Tratamento
19.
Circ J ; 86(11): 1740-1744, 2022 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-35387922

RESUMO

BACKGROUND: Transcatheter mitral valve repair with the MitraClip system has been established in selected high-risk patients. The MitraClip procedure results in a relatively large iatrogenic atrial septal defect (iASD). This study aimed to investigate the prevalence and clinical course of iASD requiring transcatheter closure following the MitraClip procedure.Methods and Results: This study was conducted at all 59 institutions that perform transcatheter mitral valve repair with the MitraClip system in Japan. The data of patients on whom transcatheter iASD closure was performed were collected. Of the 2,722 patients who underwent the MitraClip procedure, 30 (1%) required transcatheter iASD closure. The maximum iASD size was 9±4 mm (range, 3-18 mm). The common clinical course of transcatheter iASD closure was hypoxemia with right-to-left shunt or right-sided heart failure with left-to-right shunt. Of the 30 patients, 22 (73%) required transcatheter closure within 24 h following the MitraClip procedure, including 12 with hypoxemia and 5 with right-sided heart failure complicated with cardiogenic shock. Of the 5 patients, 2 required mechanical circulatory support devices. Twenty-one patients immediately underwent transcatheter iASD closure, and hemodynamic deteriorations were resolved; however, 1 patient died without having undergone transcatheter closure. CONCLUSIONS: Transcatheter iASD closure was required in 1% of patients who underwent the MitraClip procedure. Many of these patients immediately underwent transcatheter iASD closure because of hypoxemia with right-to-left shunt or right-sided heart failure with left-to-right shunt.


Assuntos
Insuficiência Cardíaca , Comunicação Interatrial , Insuficiência da Valva Mitral , Humanos , Valva Mitral/cirurgia , Cateterismo Cardíaco/efeitos adversos , Doença Iatrogênica , Comunicação Interatrial/cirurgia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Hipóxia , Resultado do Tratamento
20.
J Cardiol ; 80(2): 162-166, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35287999

RESUMO

BACKGROUND: The distal radial approach (DRA) has been proposed as an alternative approach for coronary angiography (CAG) and percutaneous coronary intervention (PCI). However, its outcomes in hemodialysis (HD) patients have not been well studied in detail. We aimed to determine the feasibility and safety of coronary intervention with the DRA for HD patients. METHODS: We performed CAG or PCI with the DRA in 2500 consecutive patients between October 2018 and February 2020. The patients included 98 HD patients (HD group) and 2402 non-HD patients (non-HD group). The primary endpoints were the rates of procedural success and puncture site-related complications. The secondary endpoints were puncture site-related complications one year after the procedure. As a subanalysis, we also compared the outcomes on the basis of CAG and PCI. RESULTS: The procedural success rates were similar in the HD and non-HD groups (80.6% vs. 82.6%, p = 0.61 for the entire cohort; 78.3% vs. 80.9%, p = 0.58 for CAG; and 86.2% vs. 88.0%, p = 0.78 for PCI). The bleeding complications rates were low and there was no difference between groups (6.1% vs. 4.1%, p = 0.33 for the entire cohort; 0% vs. 2.2%, p = 0.21 for CAG; and 20.7% vs. 10.3%, p = 0.079 for PCI). Radial artery occlusion occurred in only one patient in the HD group after the procedure. CONCLUSIONS: Although modified hemostasis methods could be necessary for HD patients undergoing PCI, coronary intervention with the DRA is feasible and safe for both HD and non-HD patients.


Assuntos
Intervenção Coronária Percutânea , Artéria Radial , Cateterismo Cardíaco , Angiografia Coronária/métodos , Estudos de Viabilidade , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Diálise Renal/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...